APC MGE Galaxy 3500 Series - User Manual

APC MGE Galaxy 3500 Series
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
MGE™Galaxy™
3500Series
10-40kVA380/400/415V
10-30kVA208/220V
Operation
Question and Answer IconNeed help?

Do you have a question about the APC MGE Galaxy 3500 Series and is the answer not in the manual?

Summary

About this Manual

Find Updates to this Manual

Instructions on how to find the latest version of the manual on the APC website.

Safety

Overview

User Interface

Description of the UPS display and navigation keys for operation.

Display Interface

Menu Tree

Operation

Modes

Details the different operational modes of the UPS system, including Normal and Bypass.

Single System without External Bypass Panel

Turn into Internal Bypass

Procedure to switch the UPS to internal bypass operation for maintenance.

Turn into Normal Operation

Procedure to return the UPS from internal bypass back to normal operation.

Perform a Total Power Off

Step-by-step instructions to completely shut down the UPS and its load.

Perform a Restart

Procedure to restart the UPS system after a power off.

Single System with External Bypass Panel

Turn into External Maintenance Bypass

Procedure to switch the UPS to external maintenance bypass mode.

Turn into Normal Operation from External Maintenance Bypass

Procedure to return the UPS from external bypass to normal operation.

Perform a Total Power Off

Steps to completely shut down the UPS and its load when using an external bypass panel.

Perform a Restart

Procedure to restart the UPS system after a total power off, when using an external bypass.

Parallel System

Turn into External Maintenance Bypass

Procedure to place UPS units in external maintenance bypass in a parallel configuration.

Turn into Normal Operation from External Maintenance Bypass

Procedure to return UPS units from external maintenance bypass to normal operation.

Perform a Restart

Steps to restart UPS units in a parallel system.

Perform a Total Power Off

Procedure for a total power off of UPS units in a parallel system.

Isolate one UPS in a Parallel System

Instructions to safely isolate a single UPS unit from a parallel system.

Turn the Isolated UPS into Normal Operation

Procedure to bring an isolated UPS unit back into normal operation in a parallel system.

Single and Parallel Systems

Control Load Output

Procedure to turn load on/off via the display interface and disconnect/connect to equipment.

Monitor System Status

Accessing status screens, logs, statistics, and diagnostic information.

Configuration

Settings

Accessing system settings for clock, alarms, and dust filter.

Clock

Procedure to change the date, time, and time-stamps in the UPS event log.

Dust Filter

Instructions for managing and resetting the dust filter surveillance settings.

Alarm Thresholds

Information on setting and understanding alarm thresholds for UPS parameters.

Change the Beeper Setup, the Contrast, and the Language

Guide to configuring beeper settings, display contrast, and language.

Maintenance

Parts Replacement

Procedure for identifying and ordering replacement parts for the UPS.

Remove the Front Panel

Step-by-step guide to safely remove the front panel of the UPS unit.

Install the Front Panel

Instructions for correctly reinstalling the front panel onto the UPS unit.

Inspect the Dust Filter

Guidelines for inspecting the dust filters for contamination and replacement needs.

Replace Dust Filter

Detailed procedure for replacing the dust filters in the UPS system.

Store the Batteries and the UPS System

Recommendations for storing battery modules and the UPS system properly.

Store the Dust Filter

Guidelines for storing dust filters under appropriate environmental conditions.

User Interface (Front)

Replace a Network Management Card

Procedure for replacing the Network Management Card in the UPS front panel.

Troubleshooting

Status and Alarm Messages

List and explanation of UPS status and alarm messages with corrective actions.

Display Messages

Detailed list of UPS display messages, their meanings, and recommended corrective actions.

APC MGE Galaxy 3500 Series Specifications

General IconGeneral
TopologyDouble Conversion Online
Transfer Time0 ms
Form FactorTower
Output Frequency50/60 Hz
Operating Temperature0 to 40°C (32 to 104°F)
Humidity0 to 95% non-condensing
Battery TypeValve-Regulated Lead Acid (VRLA)