22
XTX Second Stage Regulator Maintenance Manual
Table 5 - Test Bench Specications
TEST CONDITION ACCEPTABLE RANGE
Opening Effort
High Pressure > 50 bar gauge
Medium pressure 9.5±0.5 bar
+1.0 to +1.5 in. H
2
0 (2.5 to 3.7 mbar)
External Leak
High Pressure > 50 bar gauge
Medium Pressure 9.5±0.5 bar
No Leaks allowed
Table 4 - Torque Specications
PART NUMBER DESCRIPTION / KEY NUMBER TORQUE
AP5013/S, AP5013,
AP5013/PVDS.
Heat Exchanger (6) 3 Nm / 2.2 lbf/ft
AP5003 Spacer(6) 3 Nm / 2.2 lbf/ft
AP0203/1, AP0203/1/S Hose 5 Nm / 3.7 lbf/ft