Installation and Operation Manual
ECN: 003155
Date: 06/4/2013
43
AC-SmartStart-7608-Series_IOM Rev 04
LAN Module & Communications
Item Function
Voltage High Alert Input voltage at which a high-voltage alert is issued.
Voltage Low Alert Input voltage at which a low-voltage alert is issued.
Current Alert Current draw at which a high-current alert is issued.
Temp Alert Temperature at which a high-temperature alert is issued.
Ping Interval Seconds between attempts to contact a monitored host.
Ping Time-out Milliseconds to wait for a “ping” response from a monitored host.
Ping Threshold Number of times a “ping” fails before an alert is issued and the outlet associated with the
monitored host is turned off.
Restart Delay Number of seconds to wait before turning on the outlet associated with a monitored host
that has been turned off due to a “ping” failure.
Host 1-8 IP addresses of monitored hosts associated with outlets 1-8, respectively.
Host 1-8 check box Check box to enable Ping feature for host.
Host Test Buttons Pings the associated host and reports the result in a popup dialog box.
E-mail Recipients E-mail addresses of up to three e-mail alert recipients. Character limit of 45.
E-mail Test Buttons Sends a test e-mail to the associated e-mail recipient as a test.
Trap Recipients IP addresses of up to three SNMP trap recipients.
SMTP server IP address of SMTP server used to issue e-mail alerts.
E-mail Host ID Fully qualified host name to be used in e-mail alerts (can often be ignored or set to “foo”)
Character limit of 30.
From Address Return address appearing on e-mail alerts. Character limit of 45.
Alerts and related actions can be set up for the following events:
High input voltage
Low input voltage
High current draw
High temperature
Monitored host not detected
The Alert Setup dialog contains the following items: