11 / 60
11.3.14 h : Soldering Completion Report
【Code】 68H(‘h’)
【Function】
Soldering completion report
【Direction】
Soldering controller → External controller
【Data】
None
【Explanation】
It returns completion of soldering operation to H command that is from the upper
controller.
n case of Slide soldering, This command is not returned.
STX
‘h’
ETX SUM
11.3.15 I :
Slide Soldering Start Request
【Code】 49H(‘I’)、4AH(‘J’)
【Function】 I: Slide soldering start request
【Direction】
External controller → Soldering controller
【Data】
None
【Explanation】
Refer to “13.2 Slide Soldering Operation” about operation.
STX
‘I’
ETX SUM
STX
‘J’
ETX SUM
11.3.16
i: Slide Soldering 1st Feeding Completion Report, j: Slide Soldering Pre-heat Completion
Report, k: Slide Soldering Completion Report
【Code】 69H(‘i’)、6AH(‘j’)、6BH(‘k’)
【Function】 i: Slide soldering 1st feeding completion report
j: Slide soldering pre-heat completion report
k: Slide soldering completion report
【Direction】
Soldering controller → External controller
【Data】
None
【Explanation】
Refer to “13.2 Slide Soldering Operation” about operation.
STX
‘j’
ETX SUM
STX
‘k’
ETX SUM