11.3.17 N : Easy Slide Soldering Completion Report
【Code】 4EH(‘N’)
【Function】
Easy slide soldering completion report
【Direction】
External controller → Soldering controller
【Data】
None
【Explanation】
Refer to “13.6 Special Soldering Easy Slide Soldering Operation” about operation.
STX
‘N’
ETX SUM
11.3.18 K : Temperature Controller SV Change
【Code】 4BH(‘K’)
【Function】
Temperature controller SV change
【Direction】
External controller → Soldering controller
【Data】
Temperature 3 digits (hexadecimal notation)
【Explanation】
A specified temperature is set to “Setting temperature” of system parameter.
the maximum temperature setting, it will not set.
STX
‘K’
Set temperature ETX SUM
11.3.19 P : Manual Solder Feeding Start
【Code】 50H(‘P’)
【Function】
Manual solder feeding start
【Direction】
External controller → Soldering controller
【Data】
None
【Explanation】
When it receives this command while automatic operation is stopping, it starts to
feed the solder wire.
It continues to feed the solder until it receives Manual solder feeding end
STX
‘P’
ETX SUM
11.3.20 Q : Manual Solder Feeding End
【Code】 51H(‘Q’)
【Function】
Manual solder feeding end
【Direction】
External controller → Soldering controller
【Data】
None
【Explanation】
If it receives this command during manual solder feeding, it stops manual solder
feeding.
f it receives this command during
er revering, it ignores the command.
STX
‘Q’
ETX SUM