11.3.21 R : Manual Solder Reversing Start
【Code】 52H(‘R’)
【Function】
Manual solder reversing start
【Direction】
External controller → Soldering controller
【Data】
None
【Explanation】
If it receives this command while automatic operation is stopping, it starts solder
reversing.
If it receives this command while manual solder feeding is stopped, it ignores the
STX
‘R’
ETX SUM
11.3.22 S : Manual Solder Reversing End
【Code】 53H(‘S’)
【Function】
Manual solder reversing end
【Direction】
External controller → Soldering controller
【Data】
None
【Explanation】
If it receives this command while manual solder reversing, it stops manual solder
reversing.
If it receives this command during automatic solder feeding, it ignores the
1 2 3 4 5
STX ‘S’ ETX SUM
11.3.23 T : Manual Air Blow Start
【Code】 54H(‘T’)
【Function】
Manual air blow start
【Direction】
External controller → Soldering controller
【Data】
None
【Explanation】
It outputs air blow.
STX
‘T’
ETX SUM
11.3.24 U : Manual Air Blow End
【Code】 55H(‘U’)
【Function】
Manual air blow end
【Direction】
External controller → Soldering controller
【Data】
None
【Explanation】
It stops air blow output.
STX
‘U’
ETX SUM