13.10.4 IRON UNIT ERROR Operation (Iron Temperature Error)
1. When the temperature of the iron tip is beyond the alarm temperature range, it stops soldering.
2. When the temperature of the iron tip is beyond the alarm temperature range, IRON UNIT
ERROR signal becomes Low.
3. When the temperature of the iron tip is beyond the alarm temperature range, RUNNING signal
becomes Low.
4. When the temperature of the iron tip is beyond the alarm temperature range, END signal is
outputted.
5. The temperature of the iron tip is beyond the alarm temperature range, IRON UNIT ERROR
signal becomes High.
When the temperature of the iron tip reaches the upper limit alarm temperature or more, the
temperature control function becomes OFF.
When it is beyond the upper limit alarm temperature, if it becomes lower than the upper limit
alarm temperature and IRON UNIT ERROR signal becomes High, it starts to control the
temperature again.
When the temperature of the iron tip becomes lower than the lower limit alarm temperature, it
continues to control the temperature.
* It is not necessary that START signal is outputted as a pulse. (Except for LAN operation)
Input
Output