EasyManua.ls Logo

Apollo Seiko OMEGA - Page 7

Apollo Seiko OMEGA
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 / 60
11.3.6 c : Solder Condition Data Transfer Request
Code 63H(‘’)
Function
Solder condition data transfer request
Direction
Soldering controller External controller
Data
Solder condition number
Solder mode
SV2 setting temperature rising time
1st solder wire feeding amount
1st solder wire feeding speed
1st solder wire reversing amount
1st solder wire reversing speed
Pre-heating time
2nd solder wire feeding amount
2nd solder wire feeding speed
2nd solder wire reversing amount
2nd solder wire reversing speed
Heating time
3rd solder wire feeding amount
3rd solder wire feeding speed
3rd solder wire reversing amount
3rd solder wire reversing speed
S
older pool time
000, 101199, 201299, 301399
0, 1, 2, 3, 4, 5
4 Byte
1 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
3 Byte
Explanation
It is a return to C command from the external controller.
It is hexadecimal / 3 digits notation except for Solder condition number and Solder
mode.
It is hexadecimal / 4 digits notation in Solder condition number.
It is hexadecimal / 1 digit notation in Solder mode.
The value divided by 10 after converted it to decimal numbers becomes the actual
setting value.
If it specifies a solder condition number that does not exist in C command, it
ignores the command.
The number of Solder mode is as following;
0: Special point soldering
1: Special slide soldering
2: Special soldering point soldering (without iron up motion)
3: Special easy slide soldering
4: Pre-solder
5: Set Temp
When solder mode is “5: Set Temp”, it returns the set temperature and the process
of set temperature.
Set temperature
Process of set temperature
:
:
3 Byte
3 Byte
W
hen solder condition number is 0, it returns the air blow time of cleaning.
Solder condition number
Air blow time
: 0
:
4 Byte
3 Byte
Except for Set Temp / Cleaning Operation
1
2
3
4
5
6
54
55
56
STX
Solder condition number ETX SUM