When solder mode is “5. Set Temp”, it sets the set temperature and the process of
set temperature.
Set temperature
Process of set temperature
3 Byte
3 Byte
When solder condition number is 0, it
set
s the air blow time of cleaning.
Solder condition number
Air blow time
:
:
4 Byte
3 Byte
Except for Set Temp / Cleaning Operation
1
2
3
4
5
6
54
55
56
STX
‘D’
Solder condition number
ETX
SUM
Set Temp Operation
1
2
3
4
5
6
1
2
1
3
1
4
STX
‘D’
Solder condition number
ETX
SUM
Cleaning Operation
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
STX ‘D’
Air blow time ETX SUM
11.3.8 d : Soldering Condition Data Request Reply
Code 64H(‘d’)
Function
Soldering condition data request return
Direction
Soldering controller External controller
Data
None
Explanation
It is a reply from an external controller to D command.
I
t responds when D command is received normally.
1
2
3
4
5
STX
‘d’
ETX
SUM
11.3.9 F : Special Soldering Set Temp State Request
Code 46H(‘’)
Function
Set Temp state request
Direction
External controller Soldering controller
Data
None
Explanation
The external controller requests Set Temp state to the soldering controller.
1 2 3 4 5
STX ‘F’ ETX SUM