6. If you are replacing a broken quartz tube, check the inside of the Remedy® chamber to
insure there is no broken glass or debris inside the chamber.
7. Seat one of the O-rings inside one end of the Remedy® chamber.
8. Screw in the retaining nut until it touches the O-ring to secure the O-ring in place.
9. Slide your second O-ring over one end of the quartz tube approximately 1in to 1.25in
(2.54cm – 3.17cm).
10. Carefully slide the other end of the quartz tube into the Remedy® chamber until it
touches the O-ring secured by the retaining nut.
IMPORTANT: Be sure to slide the quartz tube into the Remedy® chamber carefully and
straight. If this is not done, the quartz tube could crack or break.
11. While guiding the end of the quartz tube with one hand, gently push the quartz tube
through the secured O-ring with the other hand until about 1in (2.54cm) of the quartz
tube is through.
12. Screw the other retaining nut into the end of the Remedy® chamber. The quartz tube may
try to slide while you are tightening this nut. To help with this, you can use a finger to
hold the quartz tube in place while you tighten the retaining nut. Hand-tighten the
retaining nuts.
IMPORTANT: Do not over-tighten the retaining nuts. If too much pressure is applied, it will
cause damage to the quartz tube.
13. Check to make sure the quartz tube is centered. You should have roughly 0.75 of an inch
(1.9cm) between the edge of the quartz tube and the end of the Remedy® chamber on
either side. If this is not the case, loosen the retaining nuts, then apply gentle pressure to
the quartz tube and slide it back and forth until you feel the quartz tube is centered
properly. Retighten the retaining nuts.
14. Carefully slide a UV lamp into the quartz tube inside the Remedy® chamber. As before,
be sure to insert the UV lamp straight and carefully, so you do not crack or break the
fragile quartz tube or the UV lamp.
15. Plug the 4-pin socket from the wire harness into the UV lamp.
16. Secure the UV lamp into the Remedy® chamber with the black retainer.
Once you have replaced the UV Lamp/Quartz tube:
Return power to the system.
Fill the tub with water.
Turn on the whirlpool motor.
Check for leaks at the ends of the Remedy® chambers. If there are drips or leaks from the
retaining nut areas, it is permissible to use a channel lock or similar tool to tighten the
nuts up to a quarter turn.
Verify that all four retaining nuts are sealing properly (no leaks).
Verify that the UV lamps are operating.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Apollo Advantage 6000 Series and is the answer not in the manual?

Apollo Advantage 6000 Series Specifications

General IconGeneral
BrandApollo
ModelAdvantage 6000 Series
CategoryBathtubs
LanguageEnglish

Related product manuals