9
Sensor Features and Functions
Power Indicator Light (Green)
On the CFS10 (battery-only powered), the POWER
icon will briefly flash every 30 seconds once the
smoke sensor has been activated.
WIRELESS will flash once per second to indicate the
wireless network is open to accept additional sensors
into the network.
Wireless Networking Light (Blue)
Warning Light (Yellow)
WARNING will flash yellow every 30 seconds,
accompanied by the horn chirp to indicate the smoke
chamber needs to be removed and cleaned.
FIRE will flash when the smoke sensor detects sufficient
quantities of smoke or heat. This is accompanied by the
sounding of the horn.
FIRE will stay on continuously if the alarm was triggered
remotely by another smoke sensor on your wireless
network. A remotely triggered sensor will exit alarm
mode after 5 minutes, unless during that time it was
able to directly detect the fire.
Fire Warning Light (Red)
WIRELESS will cease to flash one minute after the last
unit has been added to the network or immediately after
the button has been pressed.
On the CFS10-AC (AC with battery backup), the POWER
icon will glow continuously while AC powered.
WARNING can also be activated by a remote signal
from a CO Alarm. In this case, WARNING will be
solid red accompanied by 4 beeps of the horn.
Warning Light (Red)
WARNING will flash red every 30 seconds
accompanied by the horn chirp, for a minimum of 7
days, to indicate Low Battery. Replace the unit.
FIRE will continue to flash every 30 seconds (without the horn) for three
days after exiting an alarm condition, or until the front button has been
pressed and released.
WARNING will double flash red every 30 seconds
accompanied by the horn chirp, to indicate that the
smoke sensor has reached its End-of-Life. Replace
the unit.
(RED)
(YELLOW)