19
STAC6 Hardware manual
920-0029 Rev. B
11/19/2010
Connecting the Motor
Never connect or disconnect the motor while the power is on.
Note: it is highly recommended that you use a motor with a shielded cable with the STAC6.
The recommended Applied Motion motors for the STAC6 include shielded cables. See the Recommended
Motors section for a list of part numbers. All of the STAC6 motors come pre-terminated in a series configu-
ration for connection to the drive.
If your motor does not already have a connector attached or if you need to change the length of the cable,
please follow the illustration below. Be sure to connect the cable shield for safety and to minimize electrical
interference.
Motors recommended for the STAC6-220 drives can also be used with 120V drives if they are re-wired in a
parallel configuration. See the diagram below for parallel wiring.
white
green
red
black
shield
brown
orange
yellow
blue
A+ A- B+ B- FG
A+
A–
B+ B–
8
lead
motor
Series Connected 8 Leads Parallel Connected
A+
A–
B+
B–
8
lead
motor
White
Orange
Brown
Green
Red
Yellow
Blue
Black
Orange
Red
Brown
Yellow
Blue
Black
White
Green
A+
A–
B+ B–
8
lead
motor
Series Connected 8 Leads Parallel Connected
A+
A–
B+
B–
8
lead
motor
White
Orange
Brown
Green
Red
Yellow
Blue
Black
Orange
Red
Brown
Yellow
Blue
Black
White
Green