Multi monitor setups must be configured using standard procedures of the
operating system. Special features of the graphics card driver like “NVIDIA
Surround” or “AMD Eyefinity” must be disabled.
AMBIENTpx is not available while “NVIDIA G-Sync” is active.
12.
12.12.
12. Alarm configuration
Alarm configurationAlarm configuration
Alarm configuration
Select “Alarms” from the device list below the “OCTO” entry.
12.1.
12.1.12.1.
12.1. Signal output configuration
Signal output configurationSignal output configuration
Signal output configuration
The signal header can be configured as a speed signal output or as a switching
output.
Option “Power switch (53216)”: This mode can be used for emergency shutdown
of the PC, if the “signal” header is connected to the power switch header of the
motherboard using a suitable cable (art. 53216). Before connecting the cable,
make sure the signal output is configured correctly! After connecting the cable, test
the setup by deliberately creating an alarm condition. If the PC is not shut down,
the cable header connected to the motherboard must be rotated by 180 degrees
and the test has to be repeated. Emergency shutdown may result in data loss as
operating system and running programs are not shut down properly!
12.2.
12.2.12.2.
12.2. Alarm reporting and alarm limits
Alarm reporting and alarm limitsAlarm reporting and alarm limits
Alarm reporting and alarm limits
Select the data sources to be monitored and set appropriate alarm limits. If the
current reading is below the limit (flow sensors) or higher than the limit (tempera-
ture sensors), an alarm will be raised if the check box “Activate alarm evaluation”
is set for this value.
On the alarm page within the aquasuite, all sources that currently raise an alarm
are highlighted with a red background color. Alarms that have been active at least
once since device start-up, but are not active presently, are highlighted with a yel-
low background color.
Make sure only to use readings for alarm evaluation that are functional with your
specific setup.
13.
13.13.
13. Profiles
ProfilesProfiles
Profiles
Select “Profiles” from the device list below the “OCTO” entry.
The profile management can be used to to save four configurations as
profiles and activate them manually or automatically. Profile manage-
ment is a software feature of the aquasuite and requires a USB connection to the
OCTO.
© 2019-2020 Aqua Computer GmbH & Co. KG - 19 -
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aqua Computer OCTO and is the answer not in the manual?

Aqua Computer OCTO Specifications

General IconGeneral
BrandAqua Computer
ModelOCTO
CategoryController
LanguageEnglish

Related product manuals