OCTO
Flow sensor with 5.6 mm nozzle (53061)
Flow sensor “high flow” (53068)
Connection cable flow sensor for VISION (53212)
5.7.
5.7.5.7.
5.7. Connector for temperature sensors
Connector for temperature sensorsConnector for temperature sensors
Connector for temperature sensors
Connector for up to four temperature sensors.
Compatible sensors:
Temperature sensor inline G1/4 (53066)
Temperature sensor inner/outer thread G1/4 (53067)
Temperature sensor G1/4 (53147)
Temperature sensor plug&cool (53025)
Temperature sensor 70 cm (53026)
5.8.
5.8.5.8.
5.8. Connector “RGBpx 1/2”
Connector “RGBpx 1/2”Connector “RGBpx 1/2”
Connector “RGBpx 1/2”
Connectors for up to 90 addressable LEDs each. Compatible LED products and
special interconnecting cables are optional accessories and not included in deliv-
ery.
If the RGBpx product to be connected has more than one RGBpx connector, the
connector marked with the word “IN” must be used! Additional RGBpx products
may be connected to the “OUT” connector.
Compatible RGBpx products:
RGBpx LED-Strip (53268, 53269, 53270)
RGBpx lighting set (53271, 53272)
RGBpx Splitty4 (53267)
RGBpx LED ring for ULTITUBE (34115)
RGBpx LED ring for aqualis (53274, 53276)
RGBpx LED ring for 60 mm reservoir (53277)
RGBpx cable (53259, 53260, 53261, 53266)
5.9.
5.9.5.9.
5.9. Connector “signal”
Connector “signal”Connector “signal”
Connector “signal”
The signal output can be connected to the power switch header of the mother-
board using an additional specialized cable (53216, not included in delivery).
Pin assignment: Pin 1: open drain max 3.3 V / 5 mA
Pin 2: do not connect!
Pin 3: open drain max 3.3 V / 5 mA
5.10.
5.10.5.10.
5.10. Status LED
Status LEDStatus LED
Status LED
The red status LED is continuously on during normal operation. The status LED is
blinking during error conditions, for example after fan output deactivation due to
overload or faulty supply voltage. In case of errors, RGBpx LEDs connected to the
device will be blinking in red, disregarding the current LED controller setup.
© 2019-2020 Aqua Computer GmbH & Co. KG - 7 -
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aqua Computer OCTO and is the answer not in the manual?

Aqua Computer OCTO Specifications

General IconGeneral
BrandAqua Computer
ModelOCTO
CategoryController
LanguageEnglish

Related product manuals