21
Midas range commissioning
The Midas product range is pre-set to a safe maximum shower temperature. Should it be necessary to reset the
maximum temperature position, please observe the following procedure.
We recommend the MAXIMUM outlet temperature is set to 46
0
C.
1
Ensure that the hot water system is at normal maximum temperature.
! Should unacceptable damage to the temperature knob end cap occur when removing it from the temperature knob,
please contact Aqualisa customer service on 01959 560010 to arrange a replacement.
2
Turn the temperature control knob to the mid-blend position (with the button at the top of the knob).
3
Carefully remove the end cover cap using a small flat bladed screwdriver if necessary.
4
Remove the central fixing screw, pull the knob clear and set aside.
5
Turn the shower on.
6
Remove the temperature graphic ring and using a digital thermometer to record the outlet temperature of 38°C, replace
the temperature graphic ring into the required position.
We recommend the MAXIMUM outlet temperature is set to 46
0
C.
7
Turn the shower off.
8
Refit the knob, secure the fixing screw and replace the knob end cap.
!