Visage Digital concealed installation instuctions page 9
Locate the fixing lugs at the top of the
controller into position at the top of the back
plate and tilt the bottom of the controller
into place. Hold the controller in position and
secure to the back plate using the fixing screws
at the base of the controller.
13
Unscrew the single fixing on top of the
processor box and carefully tilt the lid up and
off the location lugs and pull the lid clear.
15
Connect the processor power lead to a double
pole 3 amp fuse switched spur incorporated in
the fixed wiring circuit, in accordance with
current wiring rules. Ensure that this is located
in an accessible, dry location and not in the
bathroom.
14
THIS APPLIANCE MUST BE EARTHED
We recommend protecting surface mounted cables in suitable approved
conduit to avoid the risk of damage from vermin.
The data cable and power lead should also be clipped in place with ‘P’ clips
or similar to avoid accidents.
!
Before any electrical adjustment is attempted, the electricity supply must be
turned off at the mains switch.
ELECTRICAL INSTALLATION MAY ONLY BE CARRIED OUT BY A QUALIFIED
PERSON.
!
Connect the low voltage data cable into the
socket adjacent to the temperature adjuster
as indicated on the label. Feed the cable out
of the processor box ensuring it is correctly
routed within the data cable channel.
16