EasyManua.ls Logo

ARB AIRLOCKER RD208 - Page 31

ARB AIRLOCKER RD208
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Mounting & Connecting the Electrical System
29
Figure
22.
5.2.2 Connection to an Alternate Air Source
When connecting the actuation switch to an alternate air source, the
switch(es) should be wired according to figures 23. and 24. depending
on whether one or two Air Lockers will be installed in the vehicle.
5.2.2.1 Single Air Locker System
If only one Air Locker is to be installed in the system, the switch and
solenoid should be wired according to figure 23. regardless of
whether the Air Locker has been installed in the front or rear axle of
the vehicle.
Attach the appropriate switch cover (i.e., ‘FRONT’ or ‘REAR’) to the
switch.
NOTE : Refer to figure 22. for the correct switch terminal
identification and switch orientation.
Figure
23.
SINGLE Air Locker SYSTEM
SWITCH
TERMINAL
IDENTIFICATION
UP