10
Installation space requirements
Distance between welder and wall should be more than 20cm
(
7.87
”)
; distance between two abreast
welders should be more than 30cm
(
11.82”
)
. You may refer to the below suggested reserved installation
space to confirm the installation position.
Department Front Left Side Right Side Back
Reserved Space ≥20cm/7.87
”
≥20cm/7.87
”
≥20cm/7.87
”
≥20cm/7.87
”
4.2 Electrical connection
Precautions:
All connection should be carried out by qualified professional electric operators.
All connection should be carried out when distribution box is switched off and safety is 100%
confirmed.
Cable section area of the distribution box should withstand welder’s max output.
Don’t touch with bare hands.
Don’t place heavy items on cables.
Water pipe, building metal may not be fully grounded; please don’t use them as safe earth
connection.
Every welder’s yellow/green cable should be reliably grounded.
Digital Welder Expert, Know You More