64
Sweep Profiles
The Quiver -XT SSG feature allows the
operator to select two types of sweep profiles;
Fixed and manual
A manual sweep profile gives the technician
sixteen fully configurable frequency points that
can set as required.
64-point Fixed sweep profiles can be installed
through the Q-browser program revision 5.0.0.11
and above and selected by the user as required.
Manual sweep profile
Manual sweep profile offers an on-site
configurable sweep pattern that can be changed
at any time. Output level, sweep time and markers
are also configurable.
1.TX Level
: Select this option to change the
output from +10 to +35 dBmV
2.Sweep freqs
: Select this menu option to
adjust 16 frequency points between 5 and 90
MHz.
3.
Sweep time
: Allows you to adjust the sweep
time from 5mS to 10 mS.
Markers
: allows the technician to use two 1 or
2 markers. Markers can be set to Maximum peak,
manual adjustment (<>), or off.