EasyManua.ls Logo

Arcom Digital Quiver XT - Fixed Sweep Profile; Creating a Fixed Sweep Profile

Arcom Digital Quiver XT
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
Fixed sweep profile
Fixed sweep profile allows for multiple sweep
profiles to be pre-stored in the Quiver-XT. A
stored profile can be selected from menu option
2. The illustration on the right shows that profile
#1, out of two profiles present (#1 (2)) has been
selected. Each profile consists of 64 frequency
points between 5MHz and 90 MHz.
1.TX Level
: Select this option to change the
output from +10 to +35 dBmV
2.Sweep profiles
: used for selecting pre-set
sweep profile.
3.
Sweep time
: Allows you to adjust the sweep
time from 5mS to 10 mS.
Markers
: allows the technician to use two 1 or
2 markers. Markers can be set to Maximum peak,
manual adjustment (<>), or off.
Creating a fixed sweep profile.
A fixed sweep profile is simply a formatted
text file transferred into the Quiver using the Q-
browser program.
The file format is as follows:
Line 1, File Title
Lines 2 65, Point#, :,
space
, frequency point
(MHz) including one decimal (100 KHz).
Profile filenames must be in the format
Profile#.txt.
Where # is a sequential file number. Duplicate
numbers will be overwritten without notification.