Arctic Essentials Owners Manual
23
Series Techoo

If Pump 1 does not
work in either speed,
replace appropriate
Pump 1 fuse.
If replacing the fuse
is not effective or
if Pump 1 works in
only one speed, take
voltage reading on the
corresponding in.link
connector.
*Pump 1 high and low speed
are F2 on the CE version.
Turn Pump 1 to high
speed and take voltage
reading between:
Pin 1 Pin 3
our reading should be:
240 for a
240 pump
120 for a
120 pump
Pump 1 high speed
fuse (F1)
Pump 1 low speed
fuse (F2)*
Turn Pump 1 to low
speed and take voltage
reading between:
Pin 2 Pin 3
our reading should be:
240 for a
240 pump
120 for a
120 pump
Pin Pin
Pin 1Pin 2
If voltage is as it should
be, replace Pump 1.
If not, replace spa pack.