Unsolder the spot weld between suction
pipe, discharge pipe and evaporator,
condenser,and remove suction pipe and
discharge pipe.Unsolder the spot weld
between capillary sub-assy and condenser,
evaporator, and then remove capillary
sub-assy.
Note:
1.
Before unsoldering the spot weld,
please Confirm the refrigerant is
discharged completely.
2.
When unsoldering the spot weld of
capillary,wrap the capillary with wet
cloth to prevent damage to capillary due
to high temperature. Seal the discharge
pipe outlet and suction pipe outlet with
rubber cork or gummed paper to prevent
sundries getting into it.
Lift it upwards and then remove the evaporator
and the condenser.