Hybrid electric water heater (WiFi model) – GENERAL INFORMATION
109
Average electrical power consumption
W 190
Max. electrical power consumption
W 220
Quantity of R134a refrigerant fluid
g 180 200
Quantity of fluorinated gases
Tonn.
C
O
eq.
0,2574 0,286
Global warming potential GWP 1430 1430
Max. pressure of refrigerating circuit (low-pressure side)
MPa 1,2
Max. pressure of refrigerating circuit (high-pressure side)
MPa 2,7
Max. water temperature with heat pump
°C 53 53
Amount of condensed water
l/h 0,023 (U.R. = 37 %) 0,23 (U.R. = 60 %)
EN 16147 (
A
)
COP (
A
)
2,02 1,89
Heating time (
A
)
h:min
9:21 (GREEN)
5:25 (i-MEMORY)
2:34 (BOOST)
12:18 (GREEN)
7:03 (i-MEMORY)
3:13 (BOOST)
Heating energy consumption (
A
)
kWh
1,592 (GREEN)
2,820 (i-MEMORY)
3,420 (BOOST)
2,078 (GREEN)
3,554 (i-MEMORY)
4,255 (BOOST)
Max. amount of hot water in a single intake V
max
(
A
) delivered at
53°C
l
90 118
Pes (
A
)
W
18 21
Tapping (
A
) M M
812/2013 – 814/2013 (
B
)
Q
elec
(
B
) kWh 2,890 3,086
Ƞ
wh
(
B
)
% 83,8 78,7
Mixed water at 40°C V40 (
B
)
l 90 118
Annual electricity consuption (average climatic condition) (
B
)
kWh/year 613 652
Load profile (
B
)
M M
Indoor sound power level (
C
)
dB(A) 49 49
Heating element
Heating element power
W 1200
Max. water temperature with heating element
°C 75
Power source
Voltage / max. power consumption
V / W 220-240
single-phase
/ 1420
Frequency
Hz 50
Max. current consumption
A 6,45
Protection rating
IPX4
Air side
Standard air flow rate
m
3
/h 80
Minimum volume of room of installation
m
3
13
Min. temperature of room of installation
°C 10
Max. temperature of room of installation
°C 40
Minimum air temperature (wet bulb at r.h. 90%) (
D
)
°C 10
Maximum air temperature (wet bulb at r.h. 90%) (
D
)
°C 40
(A) Values obtained with outdoor air temperature of 20 °C and 37 % relative humidity, inlet water temperature 10°C
and set temperature of 53 °C (in accordance with the provisions of EN 16147). COP calculated in GREEN and
i-MEMORY mode. The COP cannot be calculated in BOOST and PROG. modes.
(B) Values obtained with an air temperature 20 °C and 37 % relative humidity, inlet water temperature 10 °C and
temperature set 53 °C (in accordance with the provisions of 2014/C 207/03 - transitional methods of
measurement and calculation.