INSTALLATION
To calculate the size of the heating installation, refer to the
"Available pressure" graph below.
Graph representing the available circulation pump pressure
T20
o
C
0
100
200
300
400
500
600
0 200 400 600 800 1000 1200
mbar
l/h
(c)
Under oor heating
For appliances with under oor heating, it is possible but not
necessary to t a safety thermostat onto the under oor heating
outlet. For the electrical connection of the thermostat see the
section on “Electrical connections - pages 26”.
If the outlet temperature is too high, the boiler will stop both
domestic hot water and the heating production and the error
code 1 16 “ oor thermostat contact open” will appear on the
display. The boiler will restart when the thermostat is closed
during automatic resetting.
If the thermostat cannot be installed, the under oor heating
equipment must be protected by a thermostatic valve, or by a by-
pass to prevent the oor from reaching too high a temperature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston ALTEAS ONE Net Series and is the answer not in the manual?

Ariston ALTEAS ONE Net Series Specifications

General IconGeneral
TypeCondensing Boiler
Dimensions (H x W x D)745 x 400 x 385 mm
Wi-Fi ConnectivityYes
Modulation1:10
NOx EmissionsClass 6
Maximum Output35 kW
Energy Saving FeaturesAuto function
Fuel TypeNatural Gas
ControlTouch screen display
ConnectivityWi-Fi
Efficiency RatingUp to 94% (ErP A rating)

Related product manuals