TECHNICAL DATA
GENERAL
Model: ALTEAS ONE NET
30 35
CE Certi cation (pin)
0085CR0394
Boiler type
C13(X)-C23-C33(X)-C43(X)-
C53(X)-C63(X)C83(X)-C93(X)
B23-B23P-B33
POWER SPECIFICATIONS
Max/min nominal calori c ow rate (Pci) ............................ Qn
kW
28.0 / 3.0 31.0 / 3.5
Max/min nominal calori c ow rate (Pcs) .......................... Qn
kW
31.1 / 3.0 34.4 / 3.9
Domestic hot water max/min nominal calori c ow rate (Pci) ................ Qn
kW
30.0 / 3.0 34.5 / 3.5
Domestic hot water max/min nominal calori c ow rate (Pcs) ............... Qn
kW
33.3 / 3.3 38.3 / 3.9
Max/min power output (80°C-60°C) .................................... Pn
kW
27.5 / 2.8 30.3 / 3.3
Max/min power output (50°C-30°C) .................................... Pn
kW
30.3 / 3.1 33.5 / 3.6
Domestic hot water max/min power output ...................... Pn
kW
28.7 / 2.9 33.1 / 3.4
Combustion e ciency (of ue gas) %
97.8 97.8
Nominal calori c ow rate e ciency (60/80°C) Hi/Hs %
98.4 / 88.6 97.7 / 88.0
Nominal calori c ow rate e ciency (30/50°C) Hi/Hs %
108.3 / 97.5 108.0 / 97.2
E ciency at 30% at 30°C (condensation) Hi/Hs %
109.5 / 98.6 109.5 / 98.6
Minimum calori c ow rate e ciency (60/80°C) Hi/Hs %
93.0 / 83.8 93.5 / 84.2
E ciency rating (dir. 92/42/EEC) stars
★★★★
Loss of burner gas when operating %
2.2 2.2
EMISSIONS
Available air pressure Pa
100 100
NoX class class
6
Flue gas temperature (G20) (80°C-60°C) °C
66 66
CO2 content (G20) (80°C-60°C) %
8.8 8.8
CO content (0%O2) (80°C-60°C) ppm
102.2 98.8
O2 content (G20) (80°C-60°C) %
3.8 4.5
Maximum ue gas ow (G20) (80°C-60°C) Kg/h
47.6 55.7
Excess air (80°C-60°C) %
22 27
HEATING
CIRCUIT
Expansion chamber in ation pressure bar
1
Maximum heating pressure bar
3
Expansion chamber capacity l
8
Min/max heating temperature (high temperature range) °C
35 / 82
Min/max heating temperature (low temperature range) °C
20 / 45
DOMESTIC HOT WATER
CIRCUIT
Domestic hot water max/min temperature °C
36 / 60
Speci c ow rate of domestic hot water (T=30°C) l/min
14.3 16.5
Quantity of hot water T=25°C l/min
17.2 19.8
Quantity of hot water T=35°C l/min
12.3 14.1
Hot water comfort rating (EN13203) stars
★★★
Hot water minimum ow rate l/min
22
Domestic hot water max/min pressure bar
7.0 / 0.2
ELECTRICAL
Power supply frequency/voltage V/Hz
230 / 50
Total electrical power absorbed W
91 82
Circulation Pump energy e ciency index
EEI 0,23
Minimum ambient temperature for use °C
+5
Protection level for the electrical appliance IP
X5D
Weight kg
35,3 37,6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston ALTEAS ONE Net Series and is the answer not in the manual?

Ariston ALTEAS ONE Net Series Specifications

General IconGeneral
BrandAriston
ModelALTEAS ONE Net Series
CategoryBoiler
LanguageEnglish

Related product manuals