Menu - 2 - Boiler conditions
Indicates the conditions or the configurations of the boiler
5 ”
Menu - 1 - Default register
Record of the last 10 faults
x times
once
DISPLAY
ACTION CONFIGURATION
Note -- is displayed if no fault is recorded
Section Digit 1 Digit 2 Digit 3 and 4
Last fault occured 1 0 code from 01 to 99
Last but one fault occurred 1 1 code from 01 to 99
... 1 ... code from 01 to 99
Last fault occurred before the previous one 1 9 code from 01 to 99
Section Digit 1 Digit 2 Digit 3 and 4
Software version of display PCB 2 0 code from 01 to 99
Software version of main PCB 2 1 code from 01 to 99
Flue type 2 2 4 : Condensation
Fan speed (in hundreds of rpm) 2 3 from 01 to 99
Theoretical position of the 3 way valve 2 4
0 : DHW
1 : CH
DHW flow temperature in °C 2 5 from 01 to 99
CH flow temperature in °C 2 7 from 01 to 99
CH return temperature in °C 2 8 from 01 to 99
Outside temperature in °C 2 9 from 01 to 99
x times