85 / GB
MENU
SUB-MENU
PARAMETER
DESCRIPTION
RANGE DEFAULT
5 5 2 Thermoregulation type
ON/OFF
Fix Flow T
Outdoor T Only
ON/OFF
5 5 3 Slope [18;33] FC; [0-30] UFH
25 FC; 10 UFH
5 5 4 Oset [-2,5°C; +2,5°C]
0°C
5 5 6 Max T
MinT -12°C [FC];
MinT - 23°C [UFH]
12°C [FC];
23°C [UFH]
5 5 7 Min T 7°C-MaxT [FC]; 18-MaxT [UFH]
7°C [FC];
18°C [UFH]
5 5 8 Target deltaT for pump modulation cooling [-5; -20°C]
-5°C
7 ZONE MODULE (if present)
7 1 Manual Mode
7 1 0 ZM Manual mode activation OFF - ON OFF
7 1 1 Z1 Pump control OFF - ON OFF
7 1 2 Z2 Pump control OFF - ON OFF
7 1 4 Z2 Mix Valve Control
OFF
Open
Close
OFF
7 2 General Zone Module
7 2 0 Hydraulic scheme definition
Not defined
MCD
MGM II
MGM III
MGZ I
MGZ II
MGZ III
MGM II
7 2 1 FlowT Oset 0
7 2 2 Auxiliary output setting
Heat request
External pump
Alarm
Heat request
7 2 3 External temperature correction - 3 ÷ +3°C 0°C
7 3 Cooling
7 3 0 Flow_T_oset_Cool [ 0÷ 6°C]
0°C
7 8 Error History
7 8 0 Last 10 Errors
7 8 1 Reset Error List Reset? OK=Yes,esc=No
7 8 2 Last 10 Errors 2
7 8 3 Reset Error List 2 Reset? OK=Yes,esc=No
7 9 Reset Menu
7 9 0 Reset Factory Settings Reset? OK=Yes,esc=No
17 HP SYSTEM PARAMETERS
17 0 User Parameters
17 0 0 CH mode
Mode Green
Mode Standard
Mode Green
17 0 1 Quiet Mode Activation OFF - ON OFF
17 0 2 Quiet Mode start time [hh:mm] [00:00-24:00] 22:00
17 0 3 Quiet Mode end time [hh:mm] [00:00-24:00] 06:00
17 0 4 Domestic Hot Water BOOST OFF - ON OFF
17 0 5 PV Delta T DHW setpoint temp. 0 ÷ 20°C 0°C
17 1 EM Input Output Configuration
17 1 0 HV Input 1
Not Defined
Absent
EDF
SG1
External switch o signal
Absent
17 1 1 HV Input 2
Not Defined
Absent
DLSG
SG2
Absent