Description
30 / EN
1. Description
The system interface is a device that controls the heating sys-
tem. It can be used as a room thermostat and/or as a system
interface for monitoring the installations operation and config-
uring the desired settings.
1.1 Glossary of terms
Zone: a heating system can be divided into multiple hydrauli-
cally independent areas, which are referred to as “zones. Each
zone can autonomously generate a heating/cooling request
towards the heat generator. For example, a building can be di-
vided into a zone with radiant panels and a zone with radiators.
Time slot: by selecting the scheduled operating mode for a
zone, the user can define a specific time schedule. The time
schedule is divided into intervals which are referred to as “slots”;
for each slot it is possible to define a target temperature (set-
point) according to the time schedule set during the systems
configuration.
Daily 2-level time scheduling: the daily 2-level time sched-
uling allows for dividing the schedule into a maximum of 4
comfort slots and 4 reduced-temperature slots within the 24
hours of each day.
Daily multi-level time scheduling: in this mode, available
only on specially configured products, it is possible to define
up to 12 daily slots, each of which can be associated with a
specific target temperature value.
1.2 Menu navigation
The interface is equipped with a colour display, a selector and
two buttons.
The interface menus can be navigated using the “Menu button
(A), the selector (B) and the “Back button (C).
“Menu” button (A): when pressed, it opens up the
main menu.
Turning the selector (B) allows the user to perform
the following functions:
move through the items that can be selected on the
screen.
scrolling the settings for a specific function or pa-
rameter.
Pressing the selector (B) allows the user to perform
the following functions:
accessing the items that can be selected on the
screen.
confirming the settings for a specific function or pa-
rameter.
The “Back button (C) allows the user to perform the
following functions:
returning to the previous menu or sub-menu.
cancelling the entry of a setting for a specific func-
tion or parameter.
30
21°
SALOTTO
,5
°C
5
18
,0
Ve 4-GIU 12:30
1,5 bar
10°

ABC
Fig. 1