"DHW operation mode": the parameter sets the DHW
production mode.
"Standard": domestic hot water is produced using
both the heat pump and the secondary heating
source for integration.
"Green Mode": the heating elements are excluded
from the production of domestic hot water and are
activated only in case of a heat pump malfunction.
Domestic hot water production follows the auxiliary
time scheduling.
"HC - HP": domestic hot water production is only
allowed when the EDF signal is active and accord-
ing to the cheapest electricity rate. When the signal
is not active, the anti-freeze protection of the DHW
storage tank is guaranteed. To configure the EDF sig-
nal of the heat pump, see the product manual.
"HC - HP 40": domestic hot water production is
only allowed when the EDF signal is active; when
the signal is not active, the DHW cylinder is main-
tained at a temperature of 40°C or at the temper-
ature set in the parameter “DHW reduced setpoint
temp. (whichever is lower). To configure the EDF
signal of the heat pump, see the product manual.
2.11.6 Hybrid
This menu is available only if a hybrid product is installed. For
further information, see the product manual.
Hybrid Energy Manager
Quiet mode
>
Energy Manager logic
Max Ecology
Hybrid Mode
Auto
Energy tariff settings
>
Fig. 77
"Quiet mode": refer to the paragraph “Heat Pump.
"Energy Manager logic": the parameter allows to se-
lect the operation of the hybrid system based on the
“Max Saving” or “Max Ecology values.
"Hybrid Mode": the parameter allows to choose the
heat generators to be enabled in the production of
heat.
Auto”: both the heat pump and the boiler are used
to produce heat according to the setting of the pre-
vious parameter.
“Only boiler”: only the boiler is used for the produc-
tion of heat.
“Only HP”: only the heat pump is used for the pro-
duction of heat.
"Energy tariff settings": This menu allows for setting
the price for gas and electricity, as well as a reduced
electricity rate. The prices are expressed in cents. These
values are used by the hybrid Energy Manager to select
the heat generator only if the selected energy manag-
er logic is “Max Saving” and the desired hybrid mode is
Auto (the values set here are not used for the energy
consumption).