ARITERM SWEDEN AB Installation, Operation & Maintenance - 2009.02.18- 16/32
TEMPERATURE
BOILER 55(80) °C
ON
(-OFF)
AUGER EXTERNAL
MANUAL OFF
OPERATINGMODE
MAX
TEMPERATURE
FLUE GAS xx °C
OPERATING TIME
press plus key
OPERATING TIME
TOTAL
OPERATING TIME
MAX
OPERATING TIME
MIN
OPERATING TIME
EL
PELLETS STORE
press plus key
SERVICE
press plus key
ESTIMATED TIME
LEFT X d
PELLETS STORE
0,0 t
FEEDING FAKTOR
0,0 kg/h
CONSUMPTION
AVERAGE 0,0 kg/d
CONSUMPTION
TOTAL 0,0 t
AUGER EXTERNAL
TOTAL XX h
ALARM PELLETS
MIN 0,0 t
ALARM ASH
REMOVE
X ( x)
ALARM
CLEANING 0( Xh)
FLUE GAS XXX °C
MAX 240°C
BURNER TYPE
20kW
POWER HIGH
AUGER 55%
POWER HIGH
FAN 36%
POWER LOW
AUGER 55%
POWER LOW
FAN 36%
POWER MIN
AUGER 0%
POWER MIN
FAN 0%
SERVICE EL STEP
0 (0)
LEVEL MONITOR
XX (50%)
OPTICAL MONITOR
XX ( 50%)
TEST OUTPUTS
Press plus key
POWER
0
ENGLISH
ADDRESS
DEFAULT SETTINGS
v0906
DIFF TANK
NO
AUGER EXTERNAL
0
FAN
0
AUGER BURNER
0
IGNITION
0
ALARM
0
EL STEP
0
Service meny shows when
pushing same time
buttoms < and > for 5 sec.
Power menu is available
when nr. 0 is changed to
nr. 5.
Move forward when nr. on
display stops winking.
MAIN MENU
SERVICE MENU
POWER MENU
Menu is only seen when
OFF-set chosen.
FUEL
PELLETS
FUEL
PELLETS + EL
FUEL
EL
Press right arrow to leave menu.
AUGER EXTERNAL
TIME MAN. 15min
HOT STARTS
BURNER X
COLD STARTS
BURNER X
SEQUENCE
Not used!
Change nr. 0 to nr. 3 when
El STEP using.
ACTIONS CHART Biomatic+ 20 / BeQuem 20 version 0906
CLEANING
FAN 2/h
HOLDING
TIME 60min
AUGER EXTERNAL
TIME 30s
Fun must be in operation
before function of the
ignition element can be
found.
Electric heating is available
when nr 3 is selected in EL
STEP menu.
Only Biomatic+ function
ACTIONS CHART +20