Soak a cloth in disinfectant. Wipe all other contact
areas such as the outside of the bathtub, hand
control and the wheel chassis with the cloth.
Remove visual residue
Turn off all
functions.
Make sure the
tranVfer chair
is inside the
bathtub.
Put on protective gloves
and eye wear.
With water, shower and
rinse the bathtub, lift arm,
transfer chair, the loose
parts and all sides of the
accessories.
If the bathtub has an Air Spa system:
The automatic disinfection will start. Approximate time
for the automatic disinfection is 3–4 minutes.
30 seconds after the start of the automatic disinfection
the disinfection spray handle can be used.
Scrub all internal bathtub surfaces, lift arm,
transfer chair, the loose parts and the accessories
thoroughly.
Spray into the surface of the overflow
outlet.
Lift out the disinfection spray
handle.
2
5
9
3 4
1
6 7
15
16
14
Spray disinfectant into the bathtub until
the flow meter (A) shows correct mixing
value according to the Instructions for
use. Adjust if needed (B).
Mixing temperature 20°C (68°F).
Spray disinfectant in the drain. Scrub the
drain with a brush. Close the drain.
Spray disinfectant in the drain. Close
the drain.
8
10 11 12
13
Wet a new cloth with water and remove the
disinfectant. Occasionally rinse the cloth in
running water.
Push down the
disinfection
button
for 5 seconds.
Open the drain. Detach and place all
accessories at the bottom of the bathtub.
QUICK REFERENCE GUIDE - CLEANING AND DISINFECTION
Malibu/Sovereign
Continue with the steps on the next page
Disinfect with disinfection unit
Clean
Disinfect
Soak a cloth in disinfectant. Wipe all other contact
areas such as the outside of the bathtub, hand control
and the wheel chassis with the cloth.
18
Open the drain.
Rinse all parts with
plenty of water
having a temperature
of 25 °C (77 °F).
17
80
70
60
50
40
30
20
ArjoHuntleigh AB
Hans Michelsensgatan 10
211 20 Malmö, Sweden
www.arjo.com
Open the drain.
Rinse all parts with
plenty of water
having a temperature
of 25 °C (77 °F).
Spray disinfectant
on all internal
bathtub surfaces, lift
arm, transfer chair,
the loose parts and
on all sides of the
accessories.
Spray disinfectant
on all internal
bathtub surfaces, lift
arm, transfer chair,
the loose parts and
on all sides of the
accessories.
A
B
08.AZ.00_6EN • 09/2020 • Page 1/3

Other manuals for Arjohuntleigh Malibu

Question and Answer IconNeed help?

Do you have a question about the Arjohuntleigh Malibu and is the answer not in the manual?

Arjohuntleigh Malibu Specifications

General IconGeneral
BrandArjohuntleigh
ModelMalibu
CategoryMedical Equipment
LanguageEnglish

Related product manuals