NOTE:
• Do not allow any restriction to air flow patterns.
• Never place objects on the return air grill.
11. Defrosting and Water Draining
The Bilbao & Super Bilbao line of refrigerated cases is equipped with an off-cycle, Hot
Gas or Electric defrosting system.
• For the evacuation of the defrosting water it is necessary to provide suitable drainage
per any local and national codes.
7
Arneg USA - Lexington, NC
BILBAO & SUPER BILBAO
12. Glass Condensation
The multi-pane thermal insulation glass is prevented from condensation with electric
resistance heaters placed at the base of the glass assemblies.
BILBAO & SUPER BILBAO
Load Limit