The Water Flow is Low M016*
There may not be enough water flow through the heater to carry the heat away from the
heating elements. Heater startup will begin again after about 1 minute.
Flow-Related Checks
Check for low water level, suction flow restriction (filters), closed valves or trapped air.
The Water Flow has Failed M017*
There is not enough water flow through the heater to carry the heat away from the
heating element and the heater has been disabled. After the flow problem has been
resolved you must press any button to reset and begin the heater start up.
Flow-Related Checks
Check for low water level, suction flow restriction (filters), closed valves, or trapped air.
The Heater May be Dry M028*
Possible dry heater or not enough water in the heater to start it. The spa is shut down
for 15 minutes. Press any button to reset the heater startup.
Flow-Related Checks
Check for low water level, suction flow restriction (filters), closed valves, or trapped air.
The Heater is Dry M027*
There is not enough water in the heater to start and the spa is shut down. After the
problem has been resolved, you must clear the message to restart the heater.
Flow-Related Checks
Check for low water level, suction flow restriction (filters), closed valves, or trapped air.
The heater is too hot M030*
One of the water temperature has detected 118 °F (47.8 °C) in the heater and the spa
is shut down. You must clear the message when water is below 108 °F (42.2 °C).