What causes the 'Lid Latch' alarm on Arthrex Medical Equipment?
- AAnthony StanleySep 18, 2025
If the Arthrex Medical Equipment displays a 'Lid Latch' alarm, it may indicate a hardware failure. If it continues, contact Arthrex, Inc. Customer Service.
What causes the 'Lid Latch' alarm on Arthrex Medical Equipment?
If the Arthrex Medical Equipment displays a 'Lid Latch' alarm, it may indicate a hardware failure. If it continues, contact Arthrex, Inc. Customer Service.
What to do if the RBC bag is full on Arthrex Angel?
If you receive an 'RBC bag full' alert on your Arthrex Medical Equipment, empty the RBC Compartment of the Three-Compartment Reservoir Bag. After emptying, you can continue processing.
What to do if the PPP bag is full on Arthrex Medical Equipment?
If the Arthrex Medical Equipment displays a 'PPP bag full' message, empty the PPP Compartment of the Three-Compartment Reservoir Bag. After emptying it, you can continue processing.
What to do if there is air during empty on Arthrex Medical Equipment?
If you encounter 'Air during empty' while using the Arthrex Medical Equipment, check the line for any breaks or occlusions. Also, verify that the pump header is correctly loaded. If you find no issues, you can continue processing by touching the green Resume Button.
What causes the 'Pump direction error' alarm on Arthrex Medical Equipment?
If the Arthrex Medical Equipment displays a 'Pump direction error' alarm, it indicates a hardware failure. If the alarm continues, contact Arthrex, Inc. Customer Service.
What causes the 'Pump under speed' alarm on Arthrex Angel?
If the Arthrex Medical Equipment displays a 'Pump under speed' alarm, it may indicate a hardware failure. If it continues, contact Arthrex, Inc. Customer Service.
What to do if 'Power fail protocol not found' on Arthrex Angel?
If the Arthrex Medical Equipment displays 'Power fail protocol not found', the system will automatically select the default protocol for use. If you want to use a different protocol, select it from the Protocol Pull-Down Button. Keep in mind that the lost protocol may need to be recreated before it can be used.
What to do if 'Wakeup protocol not found' on Arthrex Angel?
If the Arthrex Medical Equipment shows 'Wakeup protocol not found', the system will automatically select the default protocol as the wakeup protocol. To use a different protocol, select it from the Protocol pull-down Button, and then set it as the wakeup protocol from the “Protocols” tab of the Menu Screen.
What to do if copy failed on Arthrex Angel?
If you see a 'Copy failed!' message on the Arthrex Medical Equipment, the first step is to try copying the protocol again.
How to resolve 'Another protocol has this name' error on Arthrex Angel Medical Equipment?
If you see the message 'Another protocol has this name–will be replaced' on your Arthrex Medical Equipment, change the name of the new protocol to make it unique. This will prevent it from overwriting the existing protocol.
Describes the Angel® Concentrated Platelet Rich Plasma (cPRP) System.
Specifies the intended medical uses for the Arthrex Angel System.
Lists conditions where the Angel System should not be used.
Outlines critical safety warnings for operating the Angel System.
Details important safety precautions for using the Angel System.
Explains symbols used on the device labeling and their meanings.
Provides contact details and information for technical support.
Instructions for returning used equipment to the manufacturer.
An overview of the Angel® Concentrated Platelet Rich Plasma (cPRP) System.
Explains the operational process of the Angel System.
Identifies and labels the main parts of the Angel System.
Guidelines for safely shipping and storing the Angel System.
Step-by-step instructions for installing the Angel System.
Lists necessary tools and environmental conditions for setup.
Procedures for inspecting the unit upon delivery for damage.
Steps for unpacking and assembling the Angel System.
Procedures for verifying system functionality after setup.
Instructions on how to adjust the system's date and time settings.
Description of the Angel Processing Set and its major components.
Safety warnings and precautions specific to installing the processing set.
Important steps for preparing for setup and sample aspiration.
Instructions for powering on the Angel System.
Preliminary steps and assumptions before starting the processing procedure.
Steps for loading the Angel Processing Set into the system.
Guidance on collecting blood or bone marrow samples.
Detailed steps for initiating and performing the blood separation.
Guide to creating user-defined operational protocols.
How to modify settings within an existing protocol.
Restoring protocol settings to the standard configuration.
Procedure for changing the name of a custom protocol.
Setting a default protocol for system startup.
Steps for removing custom protocols from the system.
Overview of the interface for managing protocols.
Explains system alarms and troubleshooting steps.
Steps to resolve issues with saving case data.
Steps to resolve issues with software updates.
Additional tips for resolving operational problems.
Instructions for updating the Angel System software.
Detailed explanation of the software update interface.
Procedures for periodic visual inspection of the device.
Technical specifications including performance and physical characteristics.
Details on processing volume, time, and patient requirements.
Dimensions, weight, and flow rates of the Angel System.
Operating and storage conditions for the Angel System.
Legal disclaimer regarding manufacturer responsibility.
Information on product documentation and its confidential nature.
Standards applicable to the manufacturing and safety of the device.
Contact information for Arthrex, Inc.