7.9. The AD section
7.9.1. AD Trig
Normally the AD Envelope is triggered when the ADSR Envelope receives a gate signal. But
you can use a different source instead, such as a trigger signal from an external device. To
set up this routing plug an appropriate source into the AD Trig input jack.
7.9.2. AD Attack
The Attack time of the AD Envelope can be modulated by an external source instead of by
the Attack slider in the AD ENVELOPE section. The source can be an LFO, for example. To do
this, connect a patch cable from the new source into this patch point.
7.9.3. AD Decay
The Decay time of the AD Envelope can be modulated by an external source instead of by
the Decay slider in the AD ENVELOPE section. The source can be the Mod wheel, for example.
To do this, connect a patch cable from the new source into this patch point.
7.9.4. AD Out jack
The AD Envelope is a versatile modulator, able to increase the modulation of a destination
gradually (Attack time) or cut it off suddenly (Decay time). If you want to use its stages to
control a particular destination (internal or external), connect a cable from the Out jack to
the input connector of destination parameter.