EasyManua.ls Logo

ARUSNAVI ELECTRONICS ARNAVI 5 - RS-485 Interface

ARUSNAVI ELECTRONICS ARNAVI 5
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USER MANUAL [1.4]
Page 37
ATTENTION: WHEN ACTIVATING THE ‘CAN EXT’ MODE OF RS485 INTERFACE,
THE SAME MODE OF RS232 INTERFACE MUST BE DEACTIVATED AND THE CAN
PROGRAMME NUMBER MUST BE DIFFERENT FROM ‘3’.
2.2 RS-485 INTERFACE
CAN EXT mode connecting an external CAN module via the RS485 interface.
The programme number for CAN can be specified through the configurator in the field
‘CAN:’.
An external CAN module can also be connected in parallel with one or more FLS. To do this, you
must select the mode "LLS | KUSS | PP-01".
In the section ‘Package structure’ you can mark the necessary parameters to be transmitted to the
server.