V2000 – Installation Guide
U-0623-0291.docx – Issue: 04 complete, approved
Page 30 of 40
6.3 V2000-STBY Standby Interface Card Connectors
⑨
STANDBY 100V IN: Audio from Standby Amplifier
4-way pluggable Wago
cage clamp (male)
Signal Description
100 V line audio from standby amplifier (+ve)
As above, but -ve
Two sets of connections are provided for ‘daisy-chain’ wiring from amplifier to amplifier.
Cabling
Type 1 x 2-core, twisted, screened
Termination 4-way pluggable Wago cage clamp terminal (5.08 mm) (female)
Suggested Type Suitably rated 2-core cable
⑩
LOW LEVEL STANDBY LINK: Low Level Standby Link
1
2
3
4
5
6
7
8
LOW LEVEL STANDBY LINK
1
2
3
4
5
6
7
8
Dual RJ45 jack
Pin
CAT5 Cable
(EIA 568-B)
Signal
Description
1 orange/white
Standby I/P
Balanced audio input to standby amplifier at
0 dBu (+ve)
2 orange
Standby I/P As above, but -ve
3 green/white – Not used
4 blue – Not used
5 blue/white – Not used
6 green Standby lockout For future use
7 brown/white – Not used
8 brown – Not used
Two sets of connections are provided for ‘daisy-chain’ wiring from mainframe to mainframe.
Cabling
Type Overall foil screened
Termination RJ45
Suggested Type CAT5 STP or FTP LSZH