V2000Installation Guide
U-0623-0291.docxIssue: 04 complete, approved
Page 26 of 40
6 Connections
6.1 V2000 Mainframe Connectors
AC Mains Supply
IEC 60320 C20 (male)
IEC 60445 – Conductor and Terminal Marking
Marking Wiring Colour Description
L Live Brown
230 V AC +10% / -15%
(T12 H 250 V fuse)
50 - 60 Hz
E Earth Green / Yellow
N Neutral Blue
Cabling
Type 1 x 3-core mains standard cable
Current rating (230 V): 15 A
Termination IEC 60320 C19
Suggested Type Suitably rated 3-core mains cable such as Niltox LF-319 (LSHF)
AUX OUT / NTC PROBE: Auxiliary DC Supply Output and Thermistor Probe
3.81 mm pitch plug
(Phoenix MCD 1,5/2-G1-3,81,
male)
Connector Signal Description
AUX OUT
+V auxiliary DC output (20 - 29 V) / 2 A internal cut-off
0 V supply
NTC PROBE
For connection of the thermistor lead assembly terminal.
The polarity is not relevant when wiring the thermistor lead.
A 2-metre thermistor cable assembly (ASL PN A0623910) is
supplied with the BDIST-V20000.
AUX OUT Cabling
Type 1 x 2-core
Termination 3.81 mm pitch plug (Phoenix MC 1,5/2-ST-3,81 - PN 1803578)
Suggested Type Suitably rated 2-core cable
E
L
N
SLOT 1