V2000 – Installation Guide
U-0623-0291.docx – Issue: 04 complete, approved
Page 27 of 40
③
BATTERY IN/OUT: Battery Supply Input and Charger Output
Phoenix PC 16/
2-STF-10.16 (male)
Signal Description
Battery positive input/output (21 - 28 V).
External fusing of up to 80 A is required.
Battery negative input/output
Cabling
Type
1 x 1-core red and 1 x 1-core black
Current rating: 80 A / Min. size: 16 mm
2
/ Max. length: 1 m
Termination Phoenix PC 16/ 2-STF-10,16 female connector (PHOENIX PN 1967456)
Suggested Type Suitably rated 1-core cable (red and black) such as FS LF-249 (LSHF)
④
CTRL 1 and CTRL 2: Audio-CAN, Amplifier Control Port and Relay
Standard RJ45 jack
CTRL 1
Pin CAT5 Cable
(EIA 568-B)
Signal Description
1 white/orange CAN_H Controller Area Network (High) (for future use)
2 orange CAN_L Same as above, but Low
3 white/green GND 0 V Reference
4 blue AUDIO MON+ Audio Monitor Bus (-10 dBu nominal, +ve)
5 white/blue AUDIO MON- As above, but -ve
6 green Relay COM Relay COM contact (for future use)
7 white/brown DXP EIA RS485 38400 baud (Data+)
8 brown DXN As above, but Data-
CTRL 2
Pin CAT5 Cable
(EIA 568-B)
Signal Description
1 white/orange CAN_H Controller Area Network (High) (for future use)
2 orange CAN_L Same as above, but Low
3 white/green GND 0 V Reference
4 blue AUDIO MON+ Audio Monitor Bus (-10 dBu nominal, +ve)
5 white/blue AUDIO MON- As above, but -ve
6 green Relay NO (*) Relay NO contact
7 white/brown DXP EIA RS485 38400 baud (Data+)
8 brown DXN As above, but Data-
Cabling
Type Twisted pairs, individually screened
Termination Screw-in terminals (ASL BOA) or RJ45
Suggested Type Suitably rated cable with required number of individually screened pairs