EasyManua.ls Logo

Assa Abloy 1385 - Tamper Alarm

Assa Abloy 1385
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
The tamper alarm is triggered:
When the emergency button protective cover is opened
By a door contact when a door is forced open
When the cover on the key switch module is removed
When the locking component is tampered with
ye
ye
ye
ye
rdrd
rd rd
An audible tamper alarm signal
is emitted.
The red LEDs light up.
The yellow LEDs flash.
Note
The door remains locked in the event of a 'tamper alarm'.
When a cover is closed or replaced again, the LED display and the audible
alarm continue to function.
Acknowledging the alarm and main alarm indicator:
gn
gn
gn
gn
gn
g
gn
n
gn
g
g
gn
Turn the key to the left.
Alarm is acknowledged.
The 4 green LEDs flash in pairs
in a diagonal sequence.
The alarm signal is indicated by
an LED sequence pattern.
(see 'Alarm signals' )...