55
Locking
Close door
Activate locking element.
Description Yes No
Do the four red LEDs light up?
Is the door securely locked? (test manually)
Temporary release
Activate temporary release element.
Description Yes No
The left-hand upper green LED lights up.
The three remaining green LEDs switch off one after
another in a clockwise direction.
Is the door released? (test manually)
Pre-alarm
Open the door and keep open.
Description Yes No
Does an audible alarm sound as an audible intermittent
signal after the door monitoring interval ends?
Do the four green LEDs flash in pairs?
Close door
Description Yes No
Is the door securely locked? (test manually)
Do the four red LEDs light up on the escape door
module?
Activate temporary release element.
Open the door and keep open longer than the pre-alarm delay interval.
Description Yes No
Is the danger alarm (audible alarm signal) triggered?