44
The available profiles consist of optimised pre-settings, which you can
access.
Die Parameter were factory set.
The following table shows the values of the factory setting and the possi-
ble setting range. All values in seconds.
Parameter Factory
setting
Einstellbar
from up to
Temporary release 5 1 255
Opening 50 1 3600
Monitoring 60 1 3600
Pre-alarm 10 1 3600
Alarm signal 180 0 255
Orientation signal 600 0 9999
Activation delay 0 0 255
Configuration using
FT Manager
(1385 - networked)
If changes are made, you must always select Profile
'0'
(called functions
templates in FT Manager) as it is the only place where changes can be
saved.
Note
Profile '0' is set by default when the device is delivered.
Profile Description
Input
Output
0 External temporary
release
Combined with a motorized or sole-
noid lock, or with an electric strike,
to release the door in the direction of
escape
1 External temporary
release
To connect to an external locked mode
monitoring unit
2 External temporary
release
To actuate a door operator
Profile settings