80-9316-2535-020 Rev 3 04/20
2
For special applications, a separate door and frame
preparation template is packed with these instructions. Use
this instruction sheet for installation sequence and closer
adjustments only.
Doors should be hung on ball bearing or anti-friction hinges.
A separate door stop is recommended.
Mounting Hardware Door or Frame Drill
Closer, Arm Shoe or Optional PA Bracket:
1/4-14 x 1-1/2 Oval Flat Head Mach. Screw
Wood 3/16" (4.76mm)
Closer, Arm Shoe or Optional PA Bracket:
1/4-20 x 3/4 Oval Flat Head Mach. Screw
Metal
Drill #7 (.201 dia. or 5.10mm)
Tap 1/4-20
Arm Shoe to Optional PA Bracket:
1/4-20 x 1/2 Oval Flat Head Mach. Screw
Closer:
Sleeve Nut and Bolt (SNB)
(optional)
Hollow Metal
9/32" (7.00mm) thru
3/8" (9.50mm) door face opposite to closer
Aluminum or Wood 3/8" (9.50mm) thru
Closer:
Thru Bolt and Grommet Nut (TBGN)
(optional)
All
9/32" (7.00mm) thru
3/8" (9.50mm) dia. x 3/8" (9.500mm) deep,
door face opposite to closer
Always consult door/frame manufacturer for fastener
compatibility.
Door and frame must be properly reinforced.
Adjust closing time speed between 3 and 7 seconds from
90° to 0°.
These door closers should NOT be installed on exposed side
(weather side) of exterior doors.
Dimensions are given in inches (millimeters).
Closer Adjustments
Do not over tighten
cap or cover screws.
Pinion Cap or Cover
Regular Arm
Top Jamb Mount Parallel Arm
ATTENTION:
An incorrectly installed or improperly adjusted door closer can
cause property damage or personal injury. These installation
instructions should be followed to avoid the possibility of
misapplication or misadjustment.
Latch
Backcheck
Use provided hex wrench
to turn valves. NEVER
force valves out of closer.
NEVER completely close
backcheck valve.
Door must be open to
adjust spring closing
power. Refer to chart. Do
not use a power drill.
Warranty will be void.