EasyManua.ls Logo

Assa Abloy Norton 5950 - User Manual

Assa Abloy Norton 5950
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Copyright © 2010, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
ASSA ABLOY
80-9359-0001-020 (01-14) Rev 3
1
5900 Series
Power Operator
Installation and Instruction Manual
Complies with the following: ANSI/BHMA A156.19, UL325,
UL10C, FCC, Part 15, Sub Part B, CSA C22.2 No. 247
1
4
7
2
3
5
6
9
8
Item No. Description
1 Back plate
2 Operator (5900MOT)
3 Main control unit (5900CM)
4 120VAC electrical power connection
5 Cover (5900COV)
6 On/Off/Hold open switch
7 Activation inputs
8 Cover cap
9 12/24VDC output for locking hardware
Door stop (5900DS)
10
10
WARNING: To reduce the risk of injury to person,
use this operator only with: Pedestrian Swing doors.
• Adjustable wrench
• Flat blade screwdriver (potentiometer & terminal size)
• Screwdriver (Phillips size 2)
Tape ruler
Torque wrench (up to 25lbf-ft)
• Power drill and set of drill bits
• Center punch
Wire stripper
• #7 drill 1/4-20 tap (metal frame install)
Tools required:
Glazing Material: the glazing material for swinging doors shall comply with ANSI Z97.1
Use screw pack and hardware provided to mount operator.
ASSA ABLOY

Questions and Answers

  • J
    Justin BryanAug 9, 2025
    How to fix Assa Abloy Norton 5950 when the door doesn't open and the motor doesn't start?
    • J
      Jackson JeffersonAug 10, 2025
      If the Assa Abloy Door Opening System motor doesn't start and the door doesn't open, first ensure the control switch isn't set to the OFF position by changing the setting of the ON/OFF/Hold open switch. Then, check the electrical power switch to make sure the unit is receiving power. Also, verify that the activation unit is functioning by jumping the activation input. Ensure that presence detection isn't activated by checking the detection zone for obstructions. Finally, confirm that the potentiometer SPTE is turned to 0°.
  • M
    Matthew VaughanAug 17, 2025
    What to do if Assa Abloy Norton 5950 Door Opening System door does not close?
    • M
      Molly HernandezAug 18, 2025
      If your Assa Abloy Door Opening System door isn't closing, ensure the control switch isn't set to HOLD by changing the setting of the ON/OFF/Hold open switch. Also, check for any activation of the presence input by removing objects in the detection zone. Finally, clear away anything that might be jammed beneath the door.
  • D
    David ThompsonAug 25, 2025
    How to reset spring tension on Assa Abloy Norton 5950?
    • T
      Toni BallAug 26, 2025
      To address unknown spring tension in your Assa Abloy Door Opening System operator due to too many adjustments: * Turn up the potentiometer SPTE until it is possible to loosen the door arm stop. * Remove the door stop and the arm system. * Unplug the electrical power and let the spring close. * Unplug the motor plug. * Mount the drive arm from the arm system and find the 0 tension by moving back and forth. * Loosen the arm. * Connect the motor plug. * Connect the electrical power. * Turn the SPTE pot to 210° and wait until the spindle stops turning. * Mount the door stop against the closing stop block. * Turn down SPTE to 0° - operator is now factory set.
  • T
    timothy40Aug 31, 2025
    Why Assa Abloy Norton 5950 Door Opening System motor starts but the door doesn't open?
    • D
      Diane GordonAug 31, 2025
      If the motor of your Assa Abloy Door Opening System starts but the door doesn't open, first check if the mechanical lock is locked and unlock it. Next, inspect for any obstructions beneath the door and remove them. Also, examine the electric strike plate for binding issues and select the toggle dip switch for lock release. Adjust the strike. Finally, if the arm system has come loose, turn the potentiometer SPTE until the door-stop hits the stop-block, put the door in the required open position, tighten the arm system, and turn SPTE to 0°.

Summary

Door Operator Functions and Modes

Opening Sequence Explained

Details how the door opens, including speed adjustments and obstruction handling.

Closing Sequence Explained

Describes the door closing process, force limits, and speed at latch check.

Double Door Synchronization

Instructions and considerations for setting up two operators for double doors.

General Operator Adjustments

Adjusting Spring Tension (SPTE)

Procedure for reducing or increasing the spring tension using the SPTE potentiometer.

Troubleshooting Common Issues

Door Fails to Open or Motor Not Starting

Diagnosing and resolving issues when the door does not open or the motor does not start.

Door Fails to Close or Unknown Spring Tension

Addressing problems with the door not closing or the operator having unknown spring tension.

Error Indication and Maintenance

Interpreting LED Flash Error Codes

Understanding the meaning of different LED flash frequencies for error diagnosis.

Service and Maintenance Guidelines

Procedures for authorized personnel, including power disconnection and periodic checks.

Assa Abloy Norton 5950 Specifications