All Schedule Types
Enabled/Disabled
0x65
0x(01-max
users)
Schedule(s) has been enable/disabled for
specified user ID
0x06
0xFE
Master Code
changed
0x70
0x00
Master code was changed at keypad
0x06
0x12
0x00
Master code was changed over RF
0x06
0x0E
User added
0x(01-max
users)
User added. Alarm level = user slot
number
0x06
0X0E
Duplicate Pin-code
error
0x71
0x (01-max
users)
Where Alarm level represents user slot
number
Alarm generated in response to add user
RF cmd.
This alarm is not generated when
attempting to add duplicate pin at the
keypad. The lock simply denies it and
plays the Denied. Trying to duplicate
the master code will result in a 0x71 0x00
alarm report.
0x06
0x0F
Disabled user
entered at keypad
0x83
0x(01-max
users)
A disabled user pin code was entered at
the keypad
0x06
0xFE
Valid user but
outside of schedule
0x84
0x(01-max
users)
A valid user can be both a normal user
and a Non-Access user. If a non-access
user is out of schedule this alarm will be
sent instead of the non-access alarm.
0x06
0xFE
Tamper Alarm
0xA1
0x01
keypad attempts exceed code entry limit
0x06
0X10
0x02
front escutcheon removed from main
0x06
0xFE
Battery is fully
charged
0x80
0x05
After a low battery alert was observed, the
lock was powered down and powered back
up with full battery.
0x08
0x0D

Other manuals for Assa Abloy Yale YRD216-ZW3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Assa Abloy Yale YRD216-ZW3 and is the answer not in the manual?

Assa Abloy Yale YRD216-ZW3 Specifications

General IconGeneral
BrandAssa Abloy
ModelYale YRD216-ZW3
CategoryLocks
LanguageEnglish

Related product manuals