24
Daily Repeating
Schedule
Enabled/Disabled
0x61
0x(01-max
users)
Daily Repeating Schedule(s) were
enabled/disabled for User ID specified
in Alarm Level. If Alarm Level = 0xFFFF
then all users were affected.
0x06
0xFE
Year Day Schedule
Set/Erased
0x62
0x(01-max
users)
Schedule(s) has been set/erased for
specified user ID
0x06
0xFE
Year Day Schedule
Enabled/Disabled
0x63
0x(01-max
users)
Year Day Schedule(s) were
Enabled/Disabled for User ID specified
in Alarm Level. If Alarm Level = 0xFFFF
then all users were affected.
0x06
0xFE
All Schedule Types
Erased
0x64
0x(01-max
users)
All Schedule Types were Set
(erased/set) for User ID specified in
Alarm Level. If Alarm Level = 0xFFFF
then all users were affected.
0x06
0xFE
All Schedule Types
Enabled/Disabled
0x65
0x(01-max
users)
Schedule(s) has been enable/disabled
for specified user ID
0x06
0xFE
Master Code changed
0x70
0x00
Master code was changed at keypad
0x06
0x12
0x00
Master code was changed over RF
0x06
0x0E
User added
0x(01-max
users)
User added. Alarm level = user slot
number
0x06
0X0E
Battery is fully
charged
0x80
0x05
After a low battery alert was observed,
the lock was powered down and
powered back up with full battery.
0x08
0x0D
Door Lock needs Time
set / RF Module Power
Cycled
0x82
0x00
Power to the lock was restored and the
locks RTC was cleared. The controller
should set the time to ensure proper
logging.
0x08
0x01
Disabled user entered
at keypad
0x83
0x(01-max
users)
A disabled user pin code was entered
at the keypad
0x06
0xFE
Valid user but outside
of schedule
0x84
0x(01-max
users)
A valid user can be both a normal user
and a Non-Access user. If a non-access
0x06
0xFE

Other manuals for Assa Abloy Yale YRD216-ZW3