25
user is out of schedule this alarm will
be sent instead of the non-access
alarm.
Tamper Alarm
0xA1
0x01
keypad attempts exceed code entry
limit
0x06
0X10
0x02
front escutcheon removed from main
0x06
0xFE
Low Battery Alarms*
0xA7
0x(Current
%)
Low Battery
Starting at 4.0V (0x8002 & 0x8004);
4.6V (0x8109, 0x810A, 0x8103 &
0x8104)
0x08
0x0A
0xA8
0x(Current
%)
Critical Battery Level Starting at
3.9V (0x8002 & 0x8004); 4.4V
(0x8109, 0x810A, 0x8103 &
0x8104)
0x08
0x0B
Integrated BLE Lock**
0xE2
0x00
Integrated BLE Lock
0x06
0x03
0x01
Integrated BLE Auto Relock
0x06
0x09
Integrated BLE
Unlock**
0xE3
0x00
Integrated BLE Unlock
0x06
0X04
0x01
Integrated BLE Auto Unlock
0x06
0X04
Homekit BLE Lock**
0xE4
0x00
Integrated Homekit BLE Lock
0x06
0x03
Homekit BLE Unlock**
0xE5
0x00
Integrated Homekit BLE Unlock
0x06
0X04
*The Yale lock also supports a 3
rd
low battery alarm: too low to operate. This alarm is sent out as a Battery Report
(with value = 0xFF) through the Battery Command Class. This is the last low battery alarm level before the product
stops functioning. Starting at 3.8V (0x8002 & 0x8004); 4.2V (0x8109 ,0x810A, 0x8103 & 0x8104)