NOTE: The installer should review the contents of this manual with the owner on
completion of the installation.
17. If the heater is not going to be used for a long period, disconnect it from the power
supply.
18. Always disconnect the heater before doing any maintenance.
19. CAUTION - Some parts of this product can become very hot and cause burns.
Particular attention has to be given where children and vulnerable people are
present.
The installation should always be carried out by a qualified electrician or a competent
person in accordance with the current electrical standards: HD 384 CENELEC for
Mainland Europe, IEC 60446 and BS 7671 for the United Kingdom, IEC 60445(2010) &
ET101:2008 for Ireland and IEC 60364-7-708 1988 internationally.
The energy supply to the heater must always be properly earthed. The heater must be
connected to the energy supply using the provided cable.
An over voltage category III Combined Circuit breaker and Residual Current Device
(RCD) with rated earth leakage operation not exceeding 30mA must be fitted upstream
on the supply line. The circuit breaker must have a contact opening distance of at least
3 mm.
• The heaters should always be installed only using the mounting brackets provided
or optional castors if purchased separately.
• Under no circumstances turn the heater on if it is not mounted using the brackets
supplied, the original castors accessory or if the face of the heater is flat on any
surface.
• The heater must not be recessed in the ceiling. There must be enough space
around the top of the heater to ensure adequate ventilation.
• A minimum air gap of at least 100 cm should always be allowed between the top of
the heater and a ceiling or roof.
• The heater should be at least 60 cm away from any surrounding walls.
• A distance of at least 100 cm should always be left in front of the heaters to ensure
safety
• The Heater should be mounted at a minimum of 15cm to the bottom of the heater
above floor level.
• The Heater must not be located either directly below, or in front of a socket-outlet.
• The Heater must be installed so as to prevent any control switches being able to be
touched by anyone who is in the shower or bath.
• Make sure that there is no possibility of inflammable material, combustible material
or curtains coming into contact with the heater, there is a risk of fire if this happens.
DO NOT COVER THE HEATER.
ELECTRICAL INSTALLATION NOTES