59 / 93
FG_D6_CCLINK_EN_02 / 2020-06-17
Word
Bit n°
Mask
Meaning
*ERD Only
Menu
Hexa
Dec
5
64
0001
1
Flow regulation function.
65 >79
Reserved.
6
80 > 92
Reserved.
93
2000
8192
Buzzer function.
94
4000
16384
Buzzer function Pass Part.
95
8000
32768
Buzzer function Fail Part.
7
96
0001
1
Buzzer function.
Funct
97
0002
2
Long test (x100) function.
Funct
98
0004
4
Up Contact *
Funct
99
0008
8
Down Contact *
Funct
100
0010
16
Pressure Up *
Funct
101
0020
32
Pressure Down *
Funct
102
0040
64
Step Flow *
Funct
103
0080
128
Start Press *
Funct
104
0100
256
Short Cycle *
Funct
105
0200
512
Fail up ERD chaining activation *
106
0400
1024
Fail step ERD chaining activation *
107
0800
2048
Fail down ERD chaining activation *
108
1000
4096
Fail up ERD stamping activation *
109
2000
8192
Fail step ERD stamping activation *
110
4000
16384
Fail down ERD stamping activation *
111
8000
32768
Analog output.
Funct
8
112
0001
1
Measure delay *
Funct
Example: bit number 46 (Offset function) activated on 1, will put to "4000h" the value in the third
word.
4000h is equivalent to 16384 in decimal and 0100000000000000 in binary.
In the Modbus frame, the words will follow as such: word 1 + word 2 + ….. + word n.