Line Function
Setting range
or display
Setting
increment
Basic
setting
Diagnostics heat generation
8410 Return temp HP 0... 140 °C
Setpoint (return) HP 0... 140 °C
8412 Flow temp HP 0... 140 °C
Setpoint (ow) HP 0... 140 °C
8413 Compressor modulation 0... 100%
Diagnostics consumers
8700 Outdside temperature -50... 50 °C
8701 Outside temp min
Reset ? (No, Yes)
-50... 50 °C
8702 Outside temp max
Reset ? (No, Yes)
-50... 50 °C
8740 Room temperature 1 0... 50 °C 20 °C
Room setpoint 1 4... 35 °C 20 °C
8743 Flow temperature 1 0... 140 °C 50 °C
Flow temperature setpoint 1 0... 140 °C 50 °C
8756 Flow temp cooling 1 0... 140 °C 0 °C
Flow temp setpoint cooling 1 0... 140 °C 0 °C
8770 Room temperature 2 0... 50 °C 20 °C
Room setpoint 2 4... 35 °C 20 °C
8773 Flow temperature 2 0... 140 °C 50 °C
Flow temperature setpoint 2 0... 140 °C 50 °C
8830 DHW (domestic hot water) temperature 0... 140 °C
DHW temperature setpoint 5... 80 °C 50 °C
8900 Swimming pool temperature 0... 140 °C
Swimming pool temperature setpoint 0... 35 °C 22 °C
Operation manual "1328 - EN"
Split system
- 14 -

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlantic Alfea Series and is the answer not in the manual?

Atlantic Alfea Series Specifications

General IconGeneral
BrandAtlantic
ModelAlfea Series
CategoryHeat Pump
LanguageEnglish

Related product manuals